综述

人工智能在白内障手术治疗和教学中的应用与展望

Application and prospect of artificial intelligence in the treatment and teaching of cataract surgery

:178-184
 
人工智能(artificial intelligence,AI)在白内障手术中的应用越来越广泛,二者结合对于白内障手术的术前诊断和分级管理、术中人工晶状体选择、位置预测及术后管理(视力预测、并发症预测及随访)、手术培训和教学方面均起到巨大的促进作用。诚然,AI在与白内障手术相关的管理、分析和研究中还面临着许多问题,但其广泛的应用前景不可忽视。现对AI在白内障手术治疗和教学中的应用做以总结,并对其未来的发展做出展望。
Artificial intelligence (AI) has been widely used in cataract surgery. The combination of the two can play a great role in improving preoperative diagnosis, grading management of cataract surgery, intraoperative intraocular lens selection and location prediction, postoperative management (vision prediction, complication prediction and follow-up), surgical training and teaching. It is true that AI still faces many problems in the management, analysis and research related to cataract surgery, but its broad application prospects cannot be ignored. This review summarizes the application of AI in cataract surgery and teaching, and the future prospects of AI.
综述

机器人辅助系统在眼底手术中的应用

Application of robot auxiliary system in fundus surgery

:194-199
 
传统的眼底手术要求眼科医生具备精细的操作技术,但即便拥有再精湛的操作技术,眼底手术还是存在很大的风险性。因此,为了减少手术风险,提高手术质量,对传统眼底手术进行改进是十分必要的。近年来,在我国对于人工智能产业的大力支持之下,应用于各类行业的机器人随之诞生。机器人辅助系统(robot auxiliary system,RAS)在医学领域,特别是眼科学中应用广泛。对近几年RAS应用于眼底手术的案例进行整理总结,并将RAS参与的眼底手术以及传统的眼底手术进行对比,可以发现RAS在眼底手术中的应用可以显著提高手术效率,并降低手术风险。未来RAS的发展趋势可能着重聚焦于与深度学习算法的紧密结合。通过算法对手术中的视野图像进行预测、优化,从而让高精度的眼底手术更加高效、安全。
Traditional fundus surgery requires ophthalmologists to be equipped with sophisticated operating techniques, but even with the most sophisticated operating techniques, fundus surgery still has great risks. Therefore, in order to reduce the risk of surgery and improve the quality of surgery, it is very necessary to improve the traditional fundus surgery. In recent years, with China’s strong support for the artificial intelligence industry, robots used in various industries have been born. Robot auxiliary system (RAS) is widely used in the medical field, especially in ophthalmology. By summarizing the cases of fundus surgery with RAS in recent years and comparing the fundus surgery involving RAS with traditional fundus surgery, it can be found that the application of RAS in fundus surgery can significantly improve the efficiency of surgery and reduce the risk of surgery. The future development trend of RAS may focus on the close integration with deep learning algorithms, which can predict and optimize the field of view images during surgery so that high-precision fundus surgery can be more efficient and safer.
论著

角膜 B/F 比值对年龄相关性白内障术后屈光误差的影响

The effect of corneal B/F ratio on postoperative refractive error after age-related cataract surgery

:814-821
 
目的:分析角膜后前表面曲率半径比值(B/F比值)与年龄相关性白内障患者术后屈光误差的关系,探讨B/F比值对人工晶状体(intraocular lens,IOL)度数计算精确性的影响。方法:选取2019年3—11月在天津医科大学眼科医院白内障中心就诊,并拟行单眼白内障手术的年龄相关性白内障患者共197例(197眼),术前应用Pentacam眼前节分析仪测量患者眼前节生物参数,并以B/F比值下限25%、上限25%为界将患者分为下25%组、25%~75%组、上25%组。术后3个月应用全自动电脑验光仪评估患者术后屈光状态,并计算患者术后屈光误差(postoperative refractive error,PE),比较三组平均屈光误差(mean refractive error,ME)、平均绝对误差(mean absolute error,MAE)、中位数绝对误差(median absolute error,MedAE)以及屈光误差在±0.25、±0.50、±0.75、±1.00、>±1.00 D范围内百分比差异。结果:B/F比值与年龄相关性白内障患者术后屈光误差呈中度相关(r=?0.445, P<0.001)。随着B/F比值增大,患者术后屈光状态由远视向近视漂移,术后3个月MAE、MedAE分别为0.55 D、0.46 D。屈光误差在±0.25、±0.50、±0.75、±1.00、>±1.00 D范围的百分比分别为29.4%、52.8%、71.6%、87.6%、12.7%。根据正常年龄相关性白内障人群B/F比值优化得到的矫正角膜折射指数计算角膜曲率后,MAE、MedAE分别为0.51、0.43 D,均低于矫正前(P<0.05)。结论:B/F比值对年龄相关性白内障患者术后屈光状态有影响。随着B/F比值的增加,白内障患者术后屈光状态由远视逐渐向近视漂移,且B/F比值越偏离正常平均值,患者的屈光误差绝对值越大。
Objective: To analyze the relationship between corneal B/F ratio and postoperative refractive error in age-related cataract patients, and to explore the impact of B/F ratio on the accuracy of intraocular lens power calculation. MethodsA total of 197 age-related cataract patients (197 eyes) who were treated in the cataract center of our hospital from March 2019 to November 2019 and were going to undergo monocular cataract surgery were selected. The biological parameters of the anterior segment were measured by Pentacam anterior segment analyzer before surgery, and the patients were divided into three groups (25% below the B/F ratio, 25%~75%, and 25% below the B/F ratio) with the lower limit and the upper limit of 25%. Three months after surgery, the postoperative refractive state of patients was evaluated by automatic computerized refractometer, and the postoperative refractive error (PE) was calculated, and the percentage differences of mean refractive error (ME), mean absolute error (MAE), median absolute error (MedAE) and refractive error in the range of ±0.25, ±0.50, ±0.75, ±1.00 and < ±1.00D were evaluated. Results: The B/F ratio was moderately correlated with postoperative refractive error in age-related cataract patients (r= ?0.445, P < 0.001). With the increase of B/F ratio, the refractive state of patients shifted from hyperopia to myopia after surgery, and the MAE and MedAE were 0.55 D and 0.46 D respectively in 3 months after surgery. The percentages of refractive error in the range of ±0.25, ±0.50, ±0.75, ±1.00 and < ±1.00 D were 29.4%, 52.8%, 71.6%, 87.6% and 12.7%, respectively. After adjusting the corneal curvature according to the B/F ratio of the population based on our previous study, MAE and MedAE were 0.51 D and 0.43 D, respectively, which were lower than those before correction (P< 0.05). Conclusions: There is a correlation between B/F ratio and postoperative refractive error in age-related cataract patients. As the B/F ratio increased, the refractive state of the patient gradually drifted from farsightedness to myopia after cataract surgery, and the more the B/F ratio deviated from the normal average, the greater the absolute value of the patient's refractive error.
病例报告

球形晶状体白内障术后合并黄斑水肿一例

Macular edema after cataract surgery in a patient with microspherophakia: a case report

:154-160
 
球形晶状体是一种罕见的先天性晶状体悬韧带疾病,表现为晶状体前后径增加,赤道半径减小,类似球形。临床特点包括浅前房、晶状体源性高度近视、晶状体脱位及继发青光眼等。治疗上早期可以通过验光配镜提高视力,当继发晶状体脱位及青光眼时需尽早进行手术治疗。本例报道一例72岁男性患者,因右眼视力下降2年入院。既往近视,近视逐渐加深,近2年患者双眼配镜-10D,视力无明显改善。就诊后考虑球形晶状体所致晶状体不全脱位合并白内障,入院后行囊袋拉钩固定下白内障超声乳化+人工晶状体悬吊+前段玻璃体切除术。患者术后1个月后复诊,发现黄斑水肿,予以复方平地木颗粒口服,溴芬酸钠滴眼液滴眼。2周后复诊视力及黄斑水肿明显好转。
Microspherophakia (MSP) is a rare congenital zonular dysplasia characterized by increased anteroposterior lens thickness and reduced equatorial diameter, resembling a spherical shape. The related ocular manifestations of MSP include shallow anterior chamber, lens derived high myopia, ectopia lentis and secondary glaucoma. In the early stage of MSP, vision acuity may be improved by glasses. Cataract surgery is necessary once secondary lens dislocation and glaucoma occur. A 72-year-old male hospitalized patient was reported who complained increased blurred vision of his right eye for 2 years. In the past 2 years, the power of his binocular glasses was increased to -10 diopters without significant improvement in visual acuity. Lens dislocation and phakic insufficiency caused by MSP was diagnosed after he attending clinics at the Eye and ENT Hospital of Fudan University, Shanghai, China. Phacoemulsification with scleral sutured intraocular lens (IOL) implantation surgery and anterior vitrectomy were performed. One month after operation, macular edema was found at first follow-up. Compound pingdingmu granule was taken orally and Bromfenac sodium eye drops were applied three times a day. Two weeks later, visual acuity of his right eye was improved significantly and macular edema was eliminated dramatically.
新技术交流

人工晶状体夹持技术在白内障联合玻璃体视网膜手术后囊膜破裂中的应用(视频)

Capture of intraocular lens optic for posterior capsular rupture during combined anterior and posterior segment surgery

:122-126
 
玻璃体视网膜疾病并发白内障患者行玻璃体切割术联合超声乳化白内障摘除术,即前后节联合手术,是高效的手术方式,而后囊膜破裂(posterior capsular rupture,PCR)是超声乳化白内障摘除术的术中并发症之一,能够及时、有效地处理PCR,稳定、安全地植入人工晶状体(intraocular lens,IOL),对于顺利完成后段手术,减少术后并发症十分重要。本文将对前后段联合手术中后囊膜破裂的术中处理、以及IOL光学部夹持固定法植入IOL的手术技术要点进行总结。
Combined surgery of pars plana vitrectomy (PPV) and phacoemulsification is an effective and safe way for management of retinal diseases complicated with cataract. Posterior capsular rupture (PCR) is one of the common intraoperative complications of phacoemulsification, and it is thus very important to deal with it promptly and efficiently, and ensure the subsequent procedures of intraocular lens (IOL) implantation as well as PPV. We will summarize the key points of the surgical technique for management of PCR and capture of IOL optic during combined surgery.
病例报告

准分子激光原位角膜磨镶术后白内障患者术后远视漂移一例

A case of hyperopic drift after cataract surgery in a patient with previous laser in situ keratomileusis

:874-879
 
该文报道了一例40岁女性患者,因“双眼渐进性视物模糊3个月”就诊。患者既往于2005年因高度近视行双眼准分子激光原位角膜磨镶术 (LASIK)。最佳矫正视力OD:0.2 (–11.00 DS/ –1.25 DC×170 °),OS:0.7 (–4.00 DS/ –0.75 DC×25 °)。双眼角膜透明,前房中深,晶状体混浊,豹纹状眼底伴后巩膜葡萄肿。诊断为双眼并发性白内障,并行右眼白内障超声乳化联合人工晶状体 (IOL) 植入术,术中植入+14.0 D IOL一枚,目标屈光度为–0.5 D。术后1周裸眼视力0.3,验光结果示右眼屈光度+2.75 DS,最佳矫正视力0.7。术后2周行右眼IOL置换术,由+14.0 D置换为+17.0 D。右眼术后1周裸眼视力0.8,验光结果示右眼屈光度–0.75 DC×15 °。

It is reported in this article that a 40-year-old female patient presented with "progressive blurred vision of both eyes for 3 months". The patient underwent bilateral laser in situ keratomileusis (LASIK) because of high myopia in 2005. It was recorded that her best corrected visual acuity was 0.2 (–11.00 DS/ –1.25 DC×170 °) in the right eye and 0.7 (–4.00 DS/ –0.75 DC×25 °) in the left, and clear cornea, normal anterior chamber, cloudy lens, tessellated fundus with posterior staphyloma in both eyes. The patient was diagnosed with bilateral complicated cataract. Phacoemulsification combined with intraocular lens (IOL, +14.0 diopter (D)) implantation was performed on the right eye, with the target –0.5D refractive diopter . One week after surgery, it was recorded that the uncorrected visual acuity of the right eye was 0.3, and the best corrected visual acuity was 0.7 (+2.75 DS). IOL replacement of the right eye was performed two weeks after surgery, the +14.0 D IOL was replaced by +17.0 D IOL. One week after surgery, the uncorrected visual acuity of the right eye was 0.8 (–0.75 DC×15 °).
论著

改良的“Z”形无线结经巩膜缝线固定后房型人工晶状体手术治疗先天性晶状体脱位的临床疗效评价

Clinical evaluation of modified "Z"-shaped knotless transscleral suture fixation posterior chamber intraocular lens surgery for Congenital ectopia lentis

:83-91
 
目的:通过对改良“Z”形无线结经巩膜缝线固定人工晶状体手术和传统有线结巩膜缝线固定人工晶状体手术治疗先天性晶状体脱位的比较来评价改良术式的临床疗效。方法:回顾性病例研究。纳入2018年1月—2021年3月期间于中山大学中山眼科中心行手术治疗的先天性晶状体脱位患者73例73眼,按手术方式不同将患者分为无线结组36例36眼和有线结组37例37眼。比较两组患者术前和术后1年的球镜度(DS)、柱镜度(DC)、等效球镜(SE)、最佳矫正视力(BCVA)、眼压(IOP)、眼轴长度(AL)、角膜内皮细胞计数和术后并发症的发生率。结果:两组患者术前各项观察指标组间比较差异无统计学意义(均P>0.05)。两组患者术后1年 BCVA 均较术前提高(均P<0.05),SE均较术前降低(均P<0.05)。两组患者术后1年 BCVA 、DS、DC、SE、IOP、AL、角膜内皮细胞丢失率组间比较差异均无统计学意义(均P>0.05)。术后1年,有线结组有5例(13.5%)出现缝线暴露,无线结组未出现缝线暴露,组间比较差异有统计学意义(P<0.05)。结论:改良无线结 IOL 巩膜缝线固定手术可改善CEL患者的最佳矫正视力和屈光不正,有效减少缝线暴露及相关并发症。
Objective: To evaluate the clinical efficacy of modified “Z”-shaped knotless transscleral suture fixation intraocular lens (IOL) and traditional knotted transscleral suture fixation IOL in congenital ectopia lentis. Methods: A retrospective case study. A total of 73 eyes of 73 patients with congenital ectopia lentis who underwent surgical treatment in our hospital from January 2018 to March 2021 were included. According to different surgical methods, the patients were divided into the knotless group (36 eyes) and knotted group (37 eyes). Preoperative and postoperative of 1-year diopter sphere (DS), diopter cylinder (DC), spherical equivalent (SE), best corrected visual acuity (BCVA), intraocular pressure (IOP), and axial length (AL), corneal endothelial cell counts and the occurrence of postoperative complications rate were analyzed among two groups. Results: There was no significant difference in preoperative outcome measures between the two groups (P>0.05). BCVA at 1-year postoperative was significantly better (P<0.05), and SE at 1-year postoperative was significantly lower (P<0.05). There was no significant difference in BCVA, DS, DC, SE, IOP, AL, and corneal endothelial cell loss rate between the two groups at 1-year after operation (P>0.05). One year after the operation, there were 5 cases of suture exposure (13.5%) in the knotted group and no suture exposure in the knotless group, and the difference was statistically significant (P<0.05). Conclusions: The modified knotless IOL transscleral suture fixation can improve the best corrected visual acuity and alleviate ametropia of CEL patients, and reduce suture exposure and related complications effectively.
论著

基于 OA-2000 测量的硅油取出联合白内障手术患者人工晶状体计算公式预测准确性分析

Prediction accuracy analysis of intraocular lens calculation formulas in patients undergoing silicone oil removal combined with cataract surgery based on OA-2000 measurement

:857-866
 
目的:在硅油取出联合白内障手术患者中,使用扫频源光学相干断层扫描生物测量仪OA-2000进行生物测量,比较10种人工晶状体(IOL)屈光力计算公式的准确性。方法:回顾性分析2021年3月—7月于中山大学中山眼科中心接受硅油取出联合白内障手术的患者共62例(62眼),所有患者均使用扫频源光学相干断层扫描生物测量仪OA-2000进行生物学参数测量。计算并比较新公式[Barrett Universal II (BUII)、Emmetropia Verifying Optical(EVO) 2.0、Hill-Radial Basis Function (Hill-RBF) 3.0、Hoffer QST、Kane、Pearl-DGS]及传统公式(Haigis、Hoffer Q、Holladay 1、SRK/T)的预测准确性,主要评价指标为绝对预测误差中位数(MedAE)及平均绝对预测误差(MAE)。按眼轴长度≤23 mm(组1),>23 mm且≤26 mm(组2)与>26 mm(组3)进行亚组分析。结果:6个新公式、Haigis、SRK/T公式均出现近视漂移(-0.47 ~-0.27 D,P<0.05),而HofferQ及Holladay 1公式无系统误差(P>0.05)。Kane公式的MedAE(0.55 D)及MAE(0.81 D)最小,但公式间比较差异无统计学意义(P>0.05)。组1中所有公式均出现近视漂移(-1.46~ -1.25 D,P<0.05),而其他亚组比较差异无统计学意义(-0.32 ~ 0.41 D,P>0.05)。在组1中,Pearl-DGS公式的MedAE(0.97 D)及MAE(1.26 D)最小,且优于Hill-RBF 3.0(P=0.01)及SRK/T公式(P=0.02);组2中,Kane公式具有最小的MedAE(0.44 D)及MAE(0.66 D);组3各个公式屈光预测准确性比较差异无统计学意义(P>0.05)。结论:在使用OA-2000进行术前生物测量时,Kane公式在接受硅油取出联合白内障手术患者中的预测准确性较高;而眼轴长度≤23 mm时,Pearl-DGS公式可能更为准确。
Objective: To compare the accuracy of 10 intraocular lens (IOL) power calculation formulas in patients undergoing combined silicone oil removal and cataract surgery, biometry is performed using the swept-source optical coherence tomography biometer OA-2000. Methods: A retrospective analysis. A total of 62 patients (62 eyes) who underwent combined silicone oil removal and cataract surgery in Zhongshan Ophthalmic Center, Sun Yat-sen University from March to July in 2021 were enrolled. Preoperative biometry was performed by OA-2000 in all patients. New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.0, Hill-Radial Basis Function [Hill-RBF] 3.0, Hoffer QST, Kane and Pearl-DGS) and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T) were evaluated. The median absolute prediction error (MedAE) and mean absolute prediction error (MAE) were the main parameters used to assess accuracy. Subgroup analyses were performed based on the axial length of 23 mm and 26 mm. Results: Six new-generation formulas, Haigis, and SRK/T showed myopic shift (-0.47 ~ -0.27 D, P<0.05), while no systematic bias was found in Hoffer Q and Holladay 1 displayed (P>0.05). The smallest MedAE (0.55 D) and MAE (0.81 D) were found in Kane formula, but there was no statistically significant difference compared with other formulas (P>0.05). The myopic shift (-1.46 ~ -1.25 D, P<0.05) in eyes shorter than 23 mm were found in all formulas, while there was no significant systematic bias (-0.32 ~ 0.41 D, P>0.05) in other subgroups. In axial length shorter than 23 mm, the Pearl-DGS formula stated the smallest MedAE (0.97 D) and MAE (1.26 D), and was significantly more accurate than Hill-RBF 3.0 (P=0.01) and SRK/T (P=0.02). In eyes with an axial length between 23 mm and 26 mm, the Kane formula had the lowest MedAE (0.44 D) and MAE (0.66 D). No significant difference was found in eyes longer than 26 mm. Conclusion: The Kane formula showed the highest accuracy in patients undergoing combined silicone oil removal and cataract surgery measured by OA-2000, whereas the Pearl-DGS formula could be more accurate in eyes with an axial length shorter than 23 mm.
论著

囊袋上经巩膜缝线固定IOL植入术治疗球形晶状体的有效性和安全性研究

The efficacy and safety of the application of phacoemulsification combined with supra-capsular and scleral-fixated intraocular lens implantation in microspherophakia surgery

:92-100
 
目的:探讨超声乳化晶状体吸除联合囊袋上经巩膜缝线固定人工晶状体(intraocular lens,IOL)植入术治疗球形晶状体(microspherophakia,MSP)的有效性和安全性。方法:采用回顾性分析,选取2019年1月至 2020年6月期间在复旦大学附属眼耳鼻喉科医院进行治疗的MSP患者37例(37眼),随机分为两组,纳入行超声乳化晶状体吸除联合囊袋上巩膜缝线固定IOL植入术(supra-capsular and scleral-fixated intraocular lens implantation,SCSF-IOL)的MSP患者20例(20眼)和行超声乳化晶状体吸除联合改良型囊袋张力环植入术(transscleral-fixated modified capsular tension ring and in-the-bag intraocular lens implantation,MCTR-IOL)的MSP患者17例(17眼),观察两组术后最佳矫正视力及并发症等情况。结果:两组术后最佳矫正视力比术前均有改善(P<0.001),而组间比较差异无统计学意义(P=0.326)。两组的IOL倾斜度相当(P=0.216)。预防性Nd:YAG激光后囊膜切开术在SCSFIOL术后1周至1个月进行。在SCSF-IOL组,2眼(10.00%)需要重复激光治疗,1眼(5.00%)出现囊口偏心。后囊膜混浊是MCTR组最常见并发症(6眼,35.29%)。随访期间两组均未出现IOL脱位、继发性青光眼和视网膜脱离。结论:SCSF-IOL是治疗球形晶状体的简单易行的手术方式,疗效与MCTR-IOL相当。Nd:YAG激光后囊膜切开术是预防SCSF-IOL术后囊袋并发症的必要手段。
Objective: To investigate the efficacy and safety of phacoemulsification combined with supra-capsular and scleral-fixated intraocular lens (IOL) implantation in the treatment of microspherophakia (MSP). Methods: by retrospective analysis, 37 MSP patients (37 eyes) who were treated in our hospital from January 2019 to June 2020 were randomly divided into two groups, including 20 MSP patients (20 eyes) who treated by SCSF-IOL and 17 MSP patients (17 eyes) who treated by transscleral-fixated modified capsular tension ring and in-the-bag intraocular lens implantation (MCTR-IOL). The best corrected vision and complications were observed. Results: the best corrected vision was significantly improved in both groups (P < 0.001), but there was no remarkable difference between the two groups (P = 0.326). The IOL tilt was also comparable (P = 0.216). Prophylactic Nd: YAG laser posterior capsulotomy was performed from 1 week to 1 month after the SCSF-IOL procedure. In the SCSF-IOL group, two eyes (10.00%) needed repeated laser treatment, and one eye (5.00%) had a decentered capsule opening. Posterior capsular opacification was the most common complication (6, 35.29%) in the MCTR group. No IOL dislocation, secondary glaucoma, or retinal detachment was observed during follow-up. Conclusions: SCSF-IOL is a simple and viable surgical option for managing MSP and is comparable with the MCTR-IOL. Nd: YAG laser posterior capsulotomy is a necessary mean to prevent residual capsule complications after the SCSF-IOL procedure.
论著

EYESi模拟器结合Wet-lab在白内障手术培训中的效果评价

Effect evaluation of EYESi simulator combined with Wet-lab in cataract surgery training

:736-745
 
目的:比较单一EYESi虚拟手术模拟器(Dry-lab)、Wet-lab以及两种方式联合教学在超声乳化白内障吸除显微手术培训中的效果及差异,以期探索更科学高效的教学方式。方法:选取中山大学中山眼科中心接受住院医师规范化培训的1年级住院医师18名,随机分为Dry-lab组、Wet-lab组和联合组,每组各6人,分别接受8次有效Dry-lab训练、8次Wet-lab训练、4次有效Dry-lab训练联合4次Wet-lab训练。培训前后问卷调查评估三种教学方式的模拟效果与学员满意度,并在猪眼模型上考核超声乳化白内障吸除手术的三个主要步骤,以评估学员的培训效果。结果:Dry-lab与Wet-lab训练均能有效帮助学员学习使用显微器械,操作手感较好。但在立体感(P=0.007)、与人眼操作相比近似度(P<0.001)以及对掌握技术的帮助度(P=0.003)上,Wet-lab优于Dry-lab训练;而在缩短培训用时(P<0.001)上,Dry-lab培训更具优势。联合培训模式培训效果优于单一Wet-lab训练(P=0.014)和模拟器培训(P=0.012),整体满意度高于Wet-lab训练(P=0.042)和Dry-lab培训(P=0.042)。结论:Dry-lab与Wet-lab训练在超声乳化白内障吸除显微手术培训中各有优势,而两者相结合的教学模式更为高效,培训效果更佳,整体满意度高。
Objective: To compare the effects and distinctions among three methods of phacoemulsification training: EYESi simulator (Dry-lab), Wet-lab, and a combined approach, in order to find out more scientific and efficient teaching method. Methods: 18 first-year residents undergoing residency training at Zhongshan Ophthalmic Center, Sun Yatsen University were randomly assigned to three groups: Dry-lab, Wet-lab, and Combined. Each group, consisting of 6 individuals, underwent a specific training regimen—8 sessions of effective simulator training for the Dry-lab group, 8 Wet-lab sessions for the Wet-lab group, and a combination of 4 effective simulator sessions with 4 Wet-lab sessions for the Combined group. The questionnaires were administered to assess simulation effects and student satisfaction before and after each training sessions. Additionally, the training effects were recorded in the three main steps of phacoemulsification cataract extraction surgery on a pig eye model. Results: Both the EYESi simulator and Wet-lab were proved to be effective in facilitating the learning of microscopic instrument use with commendable operating experience. However, Wet-lab is superior to the virtual simulator in terms of stereoscopic sensation (P=0.007), similarity to the human eye (P<0.001), and assistance in mastering techniques(P=0.003). Simulator training is found to be more advantageous in shortening the overall training time (P<0.001). The training effect of the joint training mode is better than that of single Wet-lab training (P=0.014) and simulator training (P=0.012), and the overall satisfaction is higher than that of Wet-lab training (P=0.042) and simulator training (P=0.042). Conclusion: The EYESi virtual surgery simulator and Wet-lab training have their advantages respectively in training for phacoemulsification cataract extraction microsurgery, and the combined teaching mode is more efficient, with better training effects and overall satisfaction.
其他期刊
  • 眼科学报

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
  • Eye Science

    主管:中华人民共和国教育部
    主办:中山大学
    承办:中山大学中山眼科中心
    主编:林浩添
    主管:中华人民共和国教育部
    主办:中山大学
    浏览
推荐阅读
出版者信息
中山眼科



中山大学