综述

玻璃体切除术后白内障患者屈光预测误差来源的研究进展

Research progress on the sources of refractive prediction error in cataract patients after vitrectomy

:143-149
 
随着微创玻璃体切除术(pars plana vitrectomy,PPV)的广泛开展和手术技术的提高,患者对手术后视觉质量的要求越来越高。白内障是PPV术后最常见并发症,而具有玻璃体切除史的白内障患者屈光变异大,预测难度高。本文综述了生物测量误差、人工晶状体屈光力计算公式选择以及有效晶状体位置预测等影响有玻璃体切除手术史的白内障患者术后屈光误差的主要因素,旨在为降低这一类特殊人群白内障术后屈光误差提供参考。
With the widespread application of minimally invasive vitrectomy and the improvement of surgical techniques, the demands of patients for better postoperative visual quality are increasing. Cataract is the most common complication after vitrectomy, whereas the refractive outcomes of cataract patients with prior vitrectomy are viable and difficult to predict. In this paper, the main factors affecting postoperative refractive error of cataract patients with a history of vitrectomy, such as biometric error, selection of intraocular lens calculation formulas and prediction of effective lens position, were reviewed in order to provide reference for reducing postoperative refractive error of this special group of cataract patients.
论著

基于 OA-2000 测量的硅油取出联合白内障手术患者人工晶状体计算公式预测准确性分析

Prediction accuracy analysis of intraocular lens calculation formulas in patients undergoing silicone oil removal combined with cataract surgery based on OA-2000 measurement

:857-866
 
目的:在硅油取出联合白内障手术患者中,使用扫频源光学相干断层扫描生物测量仪OA-2000进行生物测量,比较10种人工晶状体(IOL)屈光力计算公式的准确性。方法:回顾性分析2021年3月—7月于中山大学中山眼科中心接受硅油取出联合白内障手术的患者共62例(62眼),所有患者均使用扫频源光学相干断层扫描生物测量仪OA-2000进行生物学参数测量。计算并比较新公式[Barrett Universal II (BUII)、Emmetropia Verifying Optical(EVO) 2.0、Hill-Radial Basis Function (Hill-RBF) 3.0、Hoffer QST、Kane、Pearl-DGS]及传统公式(Haigis、Hoffer Q、Holladay 1、SRK/T)的预测准确性,主要评价指标为绝对预测误差中位数(MedAE)及平均绝对预测误差(MAE)。按眼轴长度≤23 mm(组1),>23 mm且≤26 mm(组2)与>26 mm(组3)进行亚组分析。结果:6个新公式、Haigis、SRK/T公式均出现近视漂移(-0.47 ~-0.27 D,P<0.05),而HofferQ及Holladay 1公式无系统误差(P>0.05)。Kane公式的MedAE(0.55 D)及MAE(0.81 D)最小,但公式间比较差异无统计学意义(P>0.05)。组1中所有公式均出现近视漂移(-1.46~ -1.25 D,P<0.05),而其他亚组比较差异无统计学意义(-0.32 ~ 0.41 D,P>0.05)。在组1中,Pearl-DGS公式的MedAE(0.97 D)及MAE(1.26 D)最小,且优于Hill-RBF 3.0(P=0.01)及SRK/T公式(P=0.02);组2中,Kane公式具有最小的MedAE(0.44 D)及MAE(0.66 D);组3各个公式屈光预测准确性比较差异无统计学意义(P>0.05)。结论:在使用OA-2000进行术前生物测量时,Kane公式在接受硅油取出联合白内障手术患者中的预测准确性较高;而眼轴长度≤23 mm时,Pearl-DGS公式可能更为准确。
Objective: To compare the accuracy of 10 intraocular lens (IOL) power calculation formulas in patients undergoing combined silicone oil removal and cataract surgery, biometry is performed using the swept-source optical coherence tomography biometer OA-2000. Methods: A retrospective analysis. A total of 62 patients (62 eyes) who underwent combined silicone oil removal and cataract surgery in Zhongshan Ophthalmic Center, Sun Yat-sen University from March to July in 2021 were enrolled. Preoperative biometry was performed by OA-2000 in all patients. New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.0, Hill-Radial Basis Function [Hill-RBF] 3.0, Hoffer QST, Kane and Pearl-DGS) and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T) were evaluated. The median absolute prediction error (MedAE) and mean absolute prediction error (MAE) were the main parameters used to assess accuracy. Subgroup analyses were performed based on the axial length of 23 mm and 26 mm. Results: Six new-generation formulas, Haigis, and SRK/T showed myopic shift (-0.47 ~ -0.27 D, P<0.05), while no systematic bias was found in Hoffer Q and Holladay 1 displayed (P>0.05). The smallest MedAE (0.55 D) and MAE (0.81 D) were found in Kane formula, but there was no statistically significant difference compared with other formulas (P>0.05). The myopic shift (-1.46 ~ -1.25 D, P<0.05) in eyes shorter than 23 mm were found in all formulas, while there was no significant systematic bias (-0.32 ~ 0.41 D, P>0.05) in other subgroups. In axial length shorter than 23 mm, the Pearl-DGS formula stated the smallest MedAE (0.97 D) and MAE (1.26 D), and was significantly more accurate than Hill-RBF 3.0 (P=0.01) and SRK/T (P=0.02). In eyes with an axial length between 23 mm and 26 mm, the Kane formula had the lowest MedAE (0.44 D) and MAE (0.66 D). No significant difference was found in eyes longer than 26 mm. Conclusion: The Kane formula showed the highest accuracy in patients undergoing combined silicone oil removal and cataract surgery measured by OA-2000, whereas the Pearl-DGS formula could be more accurate in eyes with an axial length shorter than 23 mm.
封面简介
论著

EYESi模拟器结合Wet-lab在白内障手术培训中的效果评价

Effect evaluation of EYESi simulator combined with Wet-lab in cataract surgery training

:736-745
 
目的:比较单一EYESi虚拟手术模拟器(Dry-lab)、Wet-lab以及两种方式联合教学在超声乳化白内障吸除显微手术培训中的效果及差异,以期探索更科学高效的教学方式。方法:选取中山大学中山眼科中心接受住院医师规范化培训的1年级住院医师18名,随机分为Dry-lab组、Wet-lab组和联合组,每组各6人,分别接受8次有效Dry-lab训练、8次Wet-lab训练、4次有效Dry-lab训练联合4次Wet-lab训练。培训前后问卷调查评估三种教学方式的模拟效果与学员满意度,并在猪眼模型上考核超声乳化白内障吸除手术的三个主要步骤,以评估学员的培训效果。结果:Dry-lab与Wet-lab训练均能有效帮助学员学习使用显微器械,操作手感较好。但在立体感(P=0.007)、与人眼操作相比近似度(P<0.001)以及对掌握技术的帮助度(P=0.003)上,Wet-lab优于Dry-lab训练;而在缩短培训用时(P<0.001)上,Dry-lab培训更具优势。联合培训模式培训效果优于单一Wet-lab训练(P=0.014)和模拟器培训(P=0.012),整体满意度高于Wet-lab训练(P=0.042)和Dry-lab培训(P=0.042)。结论:Dry-lab与Wet-lab训练在超声乳化白内障吸除显微手术培训中各有优势,而两者相结合的教学模式更为高效,培训效果更佳,整体满意度高。
Objective: To compare the effects and distinctions among three methods of phacoemulsification training: EYESi simulator (Dry-lab), Wet-lab, and a combined approach, in order to find out more scientific and efficient teaching method. Methods: 18 first-year residents undergoing residency training at Zhongshan Ophthalmic Center, Sun Yatsen University were randomly assigned to three groups: Dry-lab, Wet-lab, and Combined. Each group, consisting of 6 individuals, underwent a specific training regimen—8 sessions of effective simulator training for the Dry-lab group, 8 Wet-lab sessions for the Wet-lab group, and a combination of 4 effective simulator sessions with 4 Wet-lab sessions for the Combined group. The questionnaires were administered to assess simulation effects and student satisfaction before and after each training sessions. Additionally, the training effects were recorded in the three main steps of phacoemulsification cataract extraction surgery on a pig eye model. Results: Both the EYESi simulator and Wet-lab were proved to be effective in facilitating the learning of microscopic instrument use with commendable operating experience. However, Wet-lab is superior to the virtual simulator in terms of stereoscopic sensation (P=0.007), similarity to the human eye (P<0.001), and assistance in mastering techniques(P=0.003). Simulator training is found to be more advantageous in shortening the overall training time (P<0.001). The training effect of the joint training mode is better than that of single Wet-lab training (P=0.014) and simulator training (P=0.012), and the overall satisfaction is higher than that of Wet-lab training (P=0.042) and simulator training (P=0.042). Conclusion: The EYESi virtual surgery simulator and Wet-lab training have their advantages respectively in training for phacoemulsification cataract extraction microsurgery, and the combined teaching mode is more efficient, with better training effects and overall satisfaction.
专家述评

人工晶状体屈光力计算:求于至精,臻于至善

Intraocular lens calculation: seeking to best, improving to perfection

:775-781
 
随着功能性人工晶状体的推广应用,白内障患者的屈光预测准确性日益受到重视。尽管人工晶状体屈光力计算公式在近年来不断发展革新,但解剖参数异常或既往有其他眼病、眼部手术史的白内障患者屈光预测仍存在挑战。根据生物学参数特点与病史选择适合的人工晶状体屈光力计算公式是准确进行白内障手术屈光预测的重要保障。
With the widespread application of functional intraocular lense (IOL), the accuracy of refractive prediction in cataract patients is increasingly important. Although IOL power calculation formulas have been innovated continuously in recent years, there are still challenges in predicting refractive powerin cataract patients with abnormal anatomical parameters, ocular comorbidities, or a history of ocular surgery. Based on the the characteristics of biological parameters and medical history to selcet appropriate IOL power formula, it is an important guarantee for accurate refractive prediction in cataract patients.