目的:比较不同预设光学区组的飞秒激光小切口基质透镜取出术(small incision lenticule extraction,SMILE)和飞秒激光制瓣联合准分子激光原位角膜磨镶术(femtosecond laser-assisted in situ keratomileuses,FS-LASIK)术后有效光学区(effective optical zone,EOZ)大小与角膜高阶像差(high order aberrations,HOAs)变化以及有效光学区大小对角膜高阶像差的影响。方法:收集2019年2月 至2020年5月来佛山市第二人民医院行激光手术的患者80例,均取右眼入组,SMILE组43例,FSLASIK组37例,按预设光学区大小分为6.5 mm和6.0 mm组,分别于术前和术后1个月应用Pentacam三维眼前节分析系统测量有效光学区及总角膜高阶像差、彗差、球差,分析不同预设光学区下SMILE组和FS-LASIK组有效光学大小及与角膜高阶像差的关系。结果:在相同预设光学区下,术后1个月SMILE组的有效光学区均大于FS-LASIK组,差异均有统计学意义(均P<0.05),且SMILE组的角膜总高阶像差、球差、彗差均较FS-LASIK组低,差异均有统计学意义(均P<0.05);对于相同手术方式,预设光学区6.0 mm较6.5 mm组,术后1个月角膜总高阶像差、球差、彗差均升高,差异均有统计学意义(均P<0.05)。结论:SMILE组和FS-LASIK组术后1个月的有效光学区均小于预设光学区,SMILE组大于FS-LASIK组;术后1个月有效光学区越大,角膜高阶像差越小;在相同预设光学区下,SMILE组术后1个月角膜高阶像差小于FS-LASIK组。
Objective: To compare the effective optical zone (EOZ) and the changes in corneal high order aberrations (HOAs) after small incision lenticule extraction (SMILE) with those after femtosecond laser-assisted in situ keratomileuses (FS-LASIK). Methods: This study included 80 subjects who underwent laser refractive surgery at the Second People’s Hospital of Foshan between February 2019 and May 2020. Only data from the right eye of each subject were analyzed. A total of 43 eyes underwent SMILE while 37 eyes received FS-LASIK. The eyes were further stratified into subgroups based on different programmed optical zones: the 6.5 mm group and the 6.0 mm group. EOZ, coma, and spherical aberration were measured with Pentacam 3D anterior segment analysis system preoperatively and one month postoperatively. In addition, the relationship between EOZ and corneal HOAs was analyzed and compared between different optical-zone groups after SMILE and FS-LASIK. Results: For the same programmed optical zone, the SMILE group achieved a significantly greater EOZ than the FS-LASIK group who was measured 1-month postoperatively did (P<0.05). Meanwhile, corneal HOAs, spherical aberration, and coma in the SMILE group are significantly lower than those in the FS-LASIK group (P<0.05). For the same procedure (SMILE or FS-LASIK), the 6.0 mm group demonstrated significantly higher corneal total HOAs, spherical aberration, and coma than the 6.5 mm group did 1-month after the surgery (P<0.05). Conclusion: In both the SMILE and the FS-LASIK groups, 1-month postoperative EOZ was smaller than the programmed optical zone. EOZ in the SMILE group was larger than that in the FS-LASIK group. The larger the 1-month postoperative EOZ was, the lower corneal HOAs were. For the same programmed optical zone, 1-month postoperative corneal HOAs in the SMILE group is lower than that in the FS-LASIK group.
目的:分析角膜后前表面曲率半径比值(B/F比值)与年龄相关性白内障患者术后屈光误差的关系,探讨B/F比值对人工晶状体(intraocular lens,IOL)度数计算精确性的影响。方法:选取2019年3—11月在天津医科大学眼科医院白内障中心就诊,并拟行单眼白内障手术的年龄相关性白内障患者共197例(197眼),术前应用Pentacam眼前节分析仪测量患者眼前节生物参数,并以B/F比值下限25%、上限25%为界将患者分为下25%组、25%~75%组、上25%组。术后3个月应用全自动电脑验光仪评估患者术后屈光状态,并计算患者术后屈光误差(postoperative refractive error,PE),比较三组平均屈光误差(mean refractive error,ME)、平均绝对误差(mean absolute error,MAE)、中位数绝对误差(median absolute error,MedAE)以及屈光误差在±0.25、±0.50、±0.75、±1.00、>±1.00 D范围内百分比差异。结果:B/F比值与年龄相关性白内障患者术后屈光误差呈中度相关(r=?0.445, P<0.001)。随着B/F比值增大,患者术后屈光状态由远视向近视漂移,术后3个月MAE、MedAE分别为0.55 D、0.46 D。屈光误差在±0.25、±0.50、±0.75、±1.00、>±1.00 D范围的百分比分别为29.4%、52.8%、71.6%、87.6%、12.7%。根据正常年龄相关性白内障人群B/F比值优化得到的矫正角膜折射指数计算角膜曲率后,MAE、MedAE分别为0.51、0.43 D,均低于矫正前(P<0.05)。结论:B/F比值对年龄相关性白内障患者术后屈光状态有影响。随着B/F比值的增加,白内障患者术后屈光状态由远视逐渐向近视漂移,且B/F比值越偏离正常平均值,患者的屈光误差绝对值越大。
Objective: To analyze the relationship between corneal B/F ratio and postoperative refractive error in age-related cataract patients, and to explore the impact of B/F ratio on the accuracy of intraocular lens power calculation. Methods: A total of 197 age-related cataract patients (197 eyes) who were treated in the cataract center of our hospital from March 2019 to November 2019 and were going to undergo monocular cataract surgery were selected. The biological parameters of the anterior segment were measured by Pentacam anterior segment analyzer before surgery, and the patients were divided into three groups (25% below the B/F ratio, 25%~75%, and 25% below the B/F ratio) with the lower limit and the upper limit of 25%. Three months after surgery, the postoperative refractive state of patients was evaluated by automatic computerized refractometer, and the postoperative refractive error (PE) was calculated, and the percentage differences of mean refractive error (ME), mean absolute error (MAE), median absolute error (MedAE) and refractive error in the range of ±0.25, ±0.50, ±0.75, ±1.00 and < ±1.00D were evaluated. Results: The B/F ratio was moderately correlated with postoperative refractive error in age-related cataract patients (r= ?0.445, P < 0.001). With the increase of B/F ratio, the refractive state of patients shifted from hyperopia to myopia after surgery, and the MAE and MedAE were 0.55 D and 0.46 D respectively in 3 months after surgery. The percentages of refractive error in the range of ±0.25, ±0.50, ±0.75, ±1.00 and < ±1.00 D were 29.4%, 52.8%, 71.6%, 87.6% and 12.7%, respectively. After adjusting the corneal curvature according to the B/F ratio of the population based on our previous study, MAE and MedAE were 0.51 D and 0.43 D, respectively, which were lower than those before correction (P< 0.05). Conclusions: There is a correlation between B/F ratio and postoperative refractive error in age-related cataract patients. As the B/F ratio increased, the refractive state of the patient gradually drifted from farsightedness to myopia after cataract surgery, and the more the B/F ratio deviated from the normal average, the greater the absolute value of the patient's refractive error.
目的:探讨运用Barrett Universal Ⅱ公式(BUⅡ公式)计算人工晶状体(intraocular lens,IOL)屈光力时,可选参数角膜横径,又称白到白(white-to-white,W T W)与晶状体厚度(lens thickness,LT)的实际应用价值。方法:采用单中心、前瞻性临床研究,连续纳入同一术者顺利进行白内障超声乳化吸除术联合MX60(IOL植入术患眼279眼,术前使用OA-2000非接触式光学生物测量仪测量眼部数据并计算IOL植入度数,代入B UⅡ公式保留或去掉可选参数WTW、LT计算预测结果,进一步根据患者眼轴长度(axial length,AL)分亚组分析。主要结局指标:随访患者至术后1个月以上,比较使用和未使用WTW和LT两个参数、BUⅡ公式预测误差(prediction error,PE)、绝对预测误差(absolute error,AE)、AE小于0.5 D所占比例。结果:总体1上,忽略W T W + LT,PE为-0.05 D(-0.26, 0.18)(P=0.011),其他参数组合的PE与0比较差异无统计学意义(P>0.05)。各参数组合的AE比较差异无统计学意义(0.22~0.23 D,P= 0.404)。同时忽略WTW + LT时AE出现最大值(+1.5 D)。应用WTW + LT、忽略WTW + LT、忽略WTW和忽略LT时纳入患者AE ≤ 0.50 D的比例分别为80.65%、79.57%、80.65%和81.36%。在各眼轴亚组中,忽略LT时,AE ≤ 0.50 D的百分比在短眼轴亚组(80.00% vs.66.67%~73.33%)与长眼轴亚组(77.78% vs. 73.33%~75.56%)中较高。在中等眼轴亚组中,AE ≤ 0.50 D百分比代入全部参数时略高(83.11% vs. 80.82%~82.19%),忽略WTW + LT计算时稍低(80.82%)。结论:使用BU Ⅱ计算IOL屈光力时,可选参数WTW和LT无论是否代入公式中,皆可得到相近的平均预测水平;但是,同时忽略WTW和LT可能出现较大预测误差。对于22 mm ≤ AL<26 mm眼,推荐代入全部参数计算;当AL≤ 22 mm或AL ≥ 26 mm,仅输入WTW的计算方法累积精确度更高,可优先采用。
Objective: To investigate the practical application value of the optional parameters of corneal horizontal diameter or white to white (WTW) and lens thickness (LT) a using Barrett Universal II formula. Methods: Single-center, prospective clinical study. Eligible 279 eyes who underwent uneventful phacoemulsification and enVista MX60 implantation by the same surgeon were consecutively enrolled. OA-2000 (Tomey, Japan) non-contact optical biometry was used to measure the ocular data and calculate the IOL implantation power preoperatively. The BU II network formula was used to retain or remove optional parameters WTW and LT, and the predicted results were calculated. Further subgroup analysis was conducted based on the patient's axial length. Main outcome measures: Follow up patients for more than 1 month after surgery, compare the proportion of using and not using WTW and LT parameters, BU II formula prediction error (PE), absolute prediction error (AE), and AE less than 0.5 D. Results: Overall, ignoring WTW + LT, the median PE was -0.05 D (-0.26, 0.18) (P = 0.011) , and there is no statistically significant difference in PE compared 0 for the other parameter combinations (P > 0.05). There was no significant difference in the median AE of each parameter combination (0.22~0.23 D, P = 0.404). While ignoring both WTW and LT, the maximum AE value (+1.5 D) was found. The proportion of patients with AE ≤ 0.50 D included in the application of WTW+LT, neglect of WTW+LT, neglect of WTW, and neglect of LT were 80.65%, 79.57%, 80.65%, and 81.36%, respectively in each axial subgroup, when LT was ignored, the percentage of AE ≤ 0.50 D was higher in the short axial subgroup (80% vs. 66.67%~73.33%) and the long axial subgroup (77.78% vs. 73.33%~75.56%). In the subgroup of moderate eye axis, the percentage of AE ≤ 0.50 D was slightly higher when all parameters were substituted (83.11% vs. 80.82%~82.19%), and slightly lower when WTW+LT calculation was ignored (80.82%). Conclusions: When applying Barrett Universal II to calculate the refractive power of artificial lenses, the optional parameters WTW and LT can obtain similar average prediction levels regardless of whether they are substituted into the formula; However, ignoring both WTW and LT may result in significant prediction errors. For eyes with a diameter of 22 mm ≤ AL<26 mm, it is recommended to use all parameters for calculation; When AL ≤ 22 mm or AL ≥ 26 mm, the calculation method that only inputs WTW has higher cumulative accuracy, and it is suggested to be prioritized.
目的:初步评价折叠顶压球囊(foldable capsule buckle,FCB)治疗孔源性视网膜脱离(rhegmatogenous retinaldetachment,RRD)的有效性、安全性以及手术可操作性。方法:裂孔位置距角膜缘后≥15 mm的采用前瞻性临床病例研究。选择2020年3月至2021年9月在济南明水眼科医院院行FCB植入术治疗裂孔位置距角膜缘后≥15 mm的10例RRD患者(10眼)。应用眼部B型超声、眼底照相评价手术效果。根据术后有无FCB是否暴露、复视情况、排斥反应、眼球运动障碍等术后并发症的发生情况评价手术的疗效和安全性。结果:随访6个月~2年。10例RRD患者在术后通过眼部B超、眼底照相及光学相干断层扫描(opticalcoherence tomography,OCT)评估视网膜均复位。1例合并黄斑区视网膜脱离的患者视力提高。9例患者术后出现复视,术后1~3个月复视消失,1例在术后4个月仍存在复视,行FCB取出,术后视网膜未出现再脱离,复视症状消失。结论:初步研究可确定折叠顶压球囊植入治疗裂孔位置比较靠后(距角膜缘后≥15 mm)且传统巩膜扣带术操作难度大的孔源性视网膜脱离安全、有效,对眼球损伤小,易于操作。
Objective: To preliminarily evaluate the effectiveness, safety and surgical operability of foldable capsule buckle (FCB) in the treatment of rhegmatogenous retinal detachment (RRD). Methods: It is a prospective clinical case study. Ten patients (10 eyes), with a distance of ≥ 15 mm from the posterior margin of the angular membrane at the location of the fissure, who underwent FCB implantation surgery for RRD at Jinan Mingshui Ophthalmology Hospital from March 2020 to September 2021 were enrolled. The surgical outcome was evaluated by B-ultrasound, fundus photography and optical coherence tomography (OCT). The surgical efficay and safety were evaluated by the postoperative complications, such as FCB exposure, diplopia, rejection, and eye movement limitation. Results: The mean follow-up time was 1 year (6 months to 2 years). Retinal reattachment was evaluated by B-ultrasound, fundus photography and OCT after operation in 10 patients. One patient with macular retinal detachment had improved visual acuity. 9 patients developed diplopia after operation, but diplopia disappears 1-3 months after operation. One patient still had diplopia 4 months after operation, and FCB was removed 4 months after operation. No retinal detachment occurred after operation, and the symptoms of diplopia disappeared.Conclusion: It is confirmed by this preliminary research that the implantation of the foldable capsule buckle is safe and effective to treat rhegmatogenous retinal detachment with a relatively posterior position (≥15 mm from the back of the corneal limbus) with little damage to the ocular and easy to operate, compared with the difficulty and complexity in traditional scleral buckling surgery.
角膜移植手术是治疗角膜病变重要且有效的手段。但对眼表功能完全失代偿、多次角膜移植排斥等类型的患者,常规同种异体角膜移植手术成功率却非常低。对于这类患者,人工角膜植入术成为复明的新希望。随着人工角膜的设计和植入方式的不断改进,人工角膜的功效及优点已渐渐突显。目前,波士顿I型(领扣型)人工角膜在全球范围内应用最为广泛。现就波士顿I型人工角膜的基本特征、临床应用及未来发展等方面进行阐述。
The corneal transplantation is an effective option for visually impaired patients with keratopathy to restore vision function. However, the success rate of allograft keratoplasty is still very low for those patients with end-stage ocular surface or repeated corneal graft rejection. For those patients, artificial keratoplasty might be a promising alternative option. The efficacy and advantages of artificial keratoplasty have been gradually highlighted, after consistent improvement of the product design and implantation procedure. Nowadays, the Boston type I (collar button) corneal prosthesis is the most widely used product around the world. In this review, the history, indications, postoperative complications and future prospect of Boston type I corneal prosthesis will be summarized.
目的:探讨白内障人群角膜屈光力(corneal refractive power,CRP)的分布特点及与眼生物学参数的相关因素分析。方法:回顾性横断面研究福州眼科医院2019年3月至2022年7月就诊的40岁以上白内障人群共23035眼,使用OA-2000测量其眼轴(axial length,AL)、CRP、前房深度(anterior chamber depth,ACD)、晶状体厚度(lens thickness,LT)、角膜水平直径即白到白(white-to-white,W T W)、中央角膜厚度(central corneal thickness,CCT)。绘制各眼生物学参数及年龄Spearman相关性热力图,绘制CRP与AL、CRP与WTW散点拟合图。将CRP与上述参数及年龄进行Spearman相关性分析,分段数据的线性关系使用Pearson分析及线性回归分析。结果:白内障人群CRP为(44.36±1.52)D,在总体数据中CRP与AL为非线性相关;但在分段数据中存在线性相关:当AL≤25.06 mm,CRP与AL负线性相关(R2 =0.397,P<0.001);当AL>25.06 mm,CRP与AL正线性相关(R2 =0.045,P<0.001);无论AL长短,CRP与WTW、CCT均呈负相关。在总体数据中,CRP与WTW也存在非线性关系;但在分段数据中存在线性相关:当10.52 mm≤WTW≤12.46 mm,CRP与WTW负线性相关(R2 =0.149,P<0.001),并与AL、ACD、CCT呈负相关。结论:CRP与AL、WTW呈非线性相关,使用CRP优化计算人工晶状体(intraocular lens,IOL)屈光力时需适当考虑AL、WTW与CRP的相关性。
Objective: To investigate the distribution characteristics of corneal refractive power (CRP), and analyze the correlation between corneal refractive power and ocular biometric parameters in cataract patients. Methods: A retrospective cross-sectional study was conducted on 2,3035 eyes of cataract patients over 40 years old, who visited Fuzhou Eye Hospital during the period between March 2019 and July 2022. The subjects' examination results of axial length (AL), corneal refractive power (CRP), anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (WTW), central corneal thickness (CCT) were measured by OA-2000. Spearman correlation thermograms of bilological parameters and age for each eyes were worked out. The plot scatter fitting plots of CRP and AL, CRP and WTW were made. Spearman correlation analysis was made among CRP, above-mentioned parameters and age. Linear relationships of the segmented data were analyzed with Pearson and linear regression analysis. Results: In the cataract patients, CRP was (44.36 ± 1.52) D. There was a non-linear correlation between CRP and AL in the total data. However, there was a linear relationship in the segmented data. When AL ≤ 25.06 mm, CRP was negatively linearly correlated with AL (R2 =0.397, P<0.001). When AL>25.06 mm, CRP was weakly positively correlated with AL (R2 =0.045, P<0.001). Regardless of the length of AL, CRP was negatively correlated with WTW and CCT. There was also a nonlinear relationship between CRP and WTW in the total data. But there was a linear correlation in the segmented data.When 10.52 mm ≤ WTW ≤ 12.46 mm, the negative linear correlation was found between CRP and WTW (R2 =0.149, P<0.001), while there was negative correlation among CRP, AL, ACD, and CCT. Conclusion: There is a non-linear correlation among CRP, AL and WTW. To optimize the calculation of intraocular lens (IOL) refractive power with CRP, it is necessary to consider the correlation between AL, WTW, and CRP.
该文报道了一例40岁女性患者,因“双眼渐进性视物模糊3个月”就诊。患者既往于2005年因高度近视行双眼准分子激光原位角膜磨镶术 (LASIK)。最佳矫正视力OD:0.2 (–11.00 DS/ –1.25 DC×170 °),OS:0.7 (–4.00 DS/ –0.75 DC×25 °)。双眼角膜透明,前房中深,晶状体混浊,豹纹状眼底伴后巩膜葡萄肿。诊断为双眼并发性白内障,并行右眼白内障超声乳化联合人工晶状体 (IOL) 植入术,术中植入+14.0 D IOL一枚,目标屈光度为–0.5 D。术后1周裸眼视力0.3,验光结果示右眼屈光度+2.75 DS,最佳矫正视力0.7。术后2周行右眼IOL置换术,由+14.0 D置换为+17.0 D。右眼术后1周裸眼视力0.8,验光结果示右眼屈光度–0.75 DC×15 °。
It is reported in this article that a 40-year-old female patient presented with "progressive blurred vision of both eyes for 3 months". The patient underwent bilateral laser in situ keratomileusis (LASIK) because of high myopia in 2005. It was recorded that her best corrected visual acuity was 0.2 (–11.00 DS/ –1.25 DC×170 °) in the right eye and 0.7 (–4.00 DS/ –0.75 DC×25 °) in the left, and clear cornea, normal anterior chamber, cloudy lens, tessellated fundus with posterior staphyloma in both eyes. The patient was diagnosed with bilateral complicated cataract. Phacoemulsification combined with intraocular lens (IOL, +14.0 diopter (D)) implantation was performed on the right eye, with the target –0.5D refractive diopter . One week after surgery, it was recorded that the uncorrected visual acuity of the right eye was 0.3, and the best corrected visual acuity was 0.7 (+2.75 DS). IOL replacement of the right eye was performed two weeks after surgery, the +14.0 D IOL was replaced by +17.0 D IOL. One week after surgery, the uncorrected visual acuity of the right eye was 0.8 (–0.75 DC×15 °).
准分子激光原位角膜磨镶术(laser-assisted in situ keratomileusis,LASIK)是矫正屈光不正的重要角膜屈光手术方式之一。经过准分子激光切削的角膜,生物测量数据发生改变。对于此类患者,通过常规测量获得的参数数据以及使用常规计算公式确定的IOL屈光度将变得不再准确,由此将会导致术后较大的屈光误差,进而影响患者的视觉质量。本文报道一例46岁的男性白内障患者。该患者既往双眼屈光不正,曾接受过LASIK手术治疗。白内障术前角膜地形图检查发现该患者双眼存在角膜偏心切削,这为IOL屈光度的确定带来困难。手术医生通过角膜地形图判断角膜切削的居中性,在特定区域内选择角膜曲率K值,并采用Barrett True K公式计算出IOL屈光度。白内障术后患眼屈光误差相对较小,视力提高,视觉质量改善。
Laser-assisted in situ keratomileusis (LASIK) is a crucial corneal refractive surgery for correcting refractive errors. The cornea, after undergoing excimer laser ablation, undergoes changes in biometric measurements. For such patients, conventional measurements and IOL power calculations based on standard formulas may no longer be accurate, leading to significant postoperative refractive errors and subsequently impacting the patient's visual quality. This article presents a case of a 46-year-old male cataract patient who had a history of refractive errors in both eyes and had previously undergone LASIK surgery. Preoperative corneal topography revealed corneal eccentric ablation in both eyes, posing challenges in determining IOL power. The surgeon assessed the centration of corneal ablation using corneal topography, selected the keratometry value (K value) within specific corneal regions, and calculated the IOL power using the Barrett True K formula. Postoperatively, the cataract patient experienced relatively minor refractive errors, leading to improved vision and enhanced visual quality.
近年来,眼部电流刺激(electrical stimulation,ES)在不同方向的研究中逐渐揭示了其在多种视网膜疾病中的潜在治疗价值。其中,经角膜电刺激(transcorneal electrical stimulation,TES)作为一种非侵入性的治疗方法,能对视网膜、视神经、眼底血管及其相关结构产生积极的影响。TES能够改善视力,在保护感光细胞和减缓疾病进展方面显示出积极效果,提高患者的生存质量,还能够在不损伤眼球的情况下调节大脑中的神经元活动,为视网膜疾病的治疗提供一种新的选择。该文对近年来TES在视网膜色素变性(retinitis pigmentosa,RP)、年龄相关性黄斑变性(age-related macular degeneration,AMD)、视网膜血管病、青光眼以及视神经病变等疾病中的应用研究进行了综述。研究发现,TES治疗是一种安全且无需手术的辅助治疗工具,具有广泛的应用前景。该文旨在为临床医师提供一个全面的TES研究概述,并深入探讨其在眼科学领域的潜在应用价值。然而,TES治疗的具体机制仍需进一步探讨,以便更好地应用于临床实践。同时,未来研究还应关注TES与其他治疗方法相结合的效果,以期为患者提供更多有效的治疗选择。
In recent years, electrical stimulation of the eye (ES) has gradually revealed its potential therapeutic value in a variety of retinal diseasesin different directions. Among them, transcorneal electrical stimulation (TES), as a non-invasive treatment, can have a positive effect on the retina, optic nerve, fundus vessels and related structures. TES can improve vision, show positive effects in protecting photoreceptor cells and slowing disease progression, improve the quality of life of patients, and can regulate neuronal activity in the brain without damaging the eyeball, providing a new option for the treatment of retinal diseases. The research on the application on TES on retinitis pigementosa (RP), age-related macular degeneration (AMD), retinal angiopathy, glaucoma and optic neuropathy are reviewed in this article. It is found in the study that TES therapy is a safe and surgery-free adjuvant therapy tool, and has a wide application prospect. The purpose of this article is to provide clinicians with a comprehensive overview of TES research,and to explore its potential application value in the field of ophthalmology. However, the specific mechanism of TES therapy still needs to be further explored in order to better apply in clinical practice. At the same time, future studies should also focus on the effect of combining TES with other treatment methods, in order to provide more effective treatment options for patients.
测试 双模态全视场光学相干层析技术的角膜缘高分辨率成像
测试 双模态全视场光学相干层析技术的角膜缘高分辨率成像