Abstract: Age-related macular degeneration (AMD) remains a leading cause of severe visual impairment in developing countries. Although dry-type AMD and geographic atrophy (GA) are progressive conditions with the associated decrease of visual functions, no well-established treatment regimen was proposed for the disease. Wet-type AMD is effectively treated with intravitreal anti-angiogenic agents, but frequent injections are a major issue for the affected patients. Recent advances in AMD genetics have provided new insights into the pathogenesis and novel therapeutic targets of AMD, but the benefits of using genetic testing and genotype-based risk models for AMD development and progression still lacks evidence. Novel AMD treatments aim to increase the interval among intravitreal injections through new therapeutic agents and modern delivery devices. Simultaneously, gene therapy for dry and wet AMD is widely studied. Although gene therapy possesses a major superiority over other novel treatments regarding a persistent cure of disease, many challenges exist in the way of its broad impact on the ocular health of AMD patients.
Abstract: Several factors drive the need for increased efficiency in telemedicine screening programs directed toward diabetic retinopathy: continually increasing prevalence of diabetes worldwide, growing awareness among physicians and patients of the importance of early detection of retinal damage, and emerging technology in artificial intelligence that enables rapid identification of vision-threatening fundus features. In this context, optimizing workflows in teleretinopathy programs becomes a priority. Recent work has revealed opportunities for improvement in areas of logistics, in particular in finding the best way to get diabetic patients in front of screening cameras as conveniently as possible, as this improves compliance and, ultimately, achieves the widest reach for detection programs. The present review discusses particular aspects of mobile screening programs in which specialized retinal cameras are deployed in a van or similar type of vehicle so that they can reach patients anywhere in order to reduce barriers to access. The rationale for implementing such programs and practical considerations are presented, along with a view toward future expansion of screening and integration with artificial intelligence platforms. Lacking standardization of format and quality control among smartphone-linked approaches at present, translation of eye clinic-based photographic techniques to community-based screening offers a means of expanding the scope of impactful screening programs without the need for adoption of significantly new technology.
Abstract: The objective of the paper is to provide a general view for automatic cup to disc ratio (CDR) assessment in fundus images. As for the cause of blindness, glaucoma ranks as the second in ocular diseases. Vision loss caused by glaucoma cannot be reversed, but the loss may be avoided if screened in the early stage of glaucoma. Thus, early screening of glaucoma is very requisite to preserve vision and maintain quality of life. Optic nerve head (ONH) assessment is a useful and practical technique among current glaucoma screening methods. Vertical CDR as one of the clinical indicators for ONH assessment, has been well-used by clinicians and professionals for the analysis and diagnosis of glaucoma. The key for automatic calculation of vertical CDR in fundus images is the segmentation of optic cup (OC) and optic disc (OD). We take a brief description of methodologies about the OC and disc optic segmentation and comprehensively presented these methods as two aspects: hand-craft feature and deep learning feature. Sliding window regression, super-pixel level, image reconstruction, super-pixel level low-rank representation (LRR), deep learning methodologies for segmentation of OD and OC have been shown. It is hoped that this paper can provide guidance and bring inspiration to other researchers. Every mentioned method has its advantages and limitations. Appropriate method should be selected or explored according to the actual situation. For automatic glaucoma screening, CDR is just the reflection for a small part of the disc, while utilizing comprehensive factors or multimodal images is the promising future direction to furthermore enhance the performance.
Abstract: The most prominent causes of loss of vision in individuals over 50 years include age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy (DR). While it is important to screen for these diseases effectively, current eye care is not properly doing so for much of the population, resulting in unfortunate visual disability and high costs for patients. Innovative functional testing can be unified with other screening methods for a more robust and safer screening and prediction of disease. The goal in the creation of functional testing modalities is to develop highly sensitive screening tests that are easy to use, accessible to all users, and inexpensive. The tests herein are deployed on an iPad with easily understood and intuitive instructions for rapid, streamlined, and automatic administration. These testing modalities could become highly sensitive screenings for early detection of potentially blinding diseases. The applications from our collaborators at AMA Optics include a cone photostress recovery test for detection of AMD and diabetic macular edema (DME), brightness balance perception for optic nerve dysfunction and especially glaucoma, color vision testing which is a broad screening tool, and visual acuity test. Machine learning with the combined structural and functional data will optimize identification of disease and prediction of outcomes. Here, we review and assess various tests of visual function that are easily administered on a tablet for screening in primary care. These user-friendly and simple screening tests allow patients to be identified in the early stages of disease for referral to specialists, proper assessment and treatment.
Abstract: Pediatric glaucoma is a potentially sight-threatening disease and is considered the second leading cause of treatable childhood blindness. Pediatric glaucoma is a clinical entity including a wide range of conditions: primary congenital glaucoma, glaucoma secondary to ocular (e.g., aniridia, Peter’s anomaly), or systemic disease (e.g., Sturge Weber) and glaucoma secondary to acquired condition (pseudophakic, traumatic, uveitic glaucoma). The treatment algorithm of childhood glaucoma is a step-by-step approach, often starting with surgery, as in primary congenital glaucoma cases. Medical therapy is also crucial in the management of pediatric glaucoma. Here we reported the results of the randomized, controlled, clinical trials carried out in children treated with topical anti-glaucoma drugs. It is worth knowing that prostaglandin analogues showed an excellent systemic safety profile, while serious systemic events have been reported in children taking topical beta-blockers. Angle surgery is the first surgical option in patients diagnosed with primary congenital glaucoma, with ab interno and ab externo approaches showing similar outcomes. Trabeculectomy in children can be troublesome, as mitomycin C (MMC) can lead to bleb complications and a higher endophthalmitis rate than in adults. Glaucoma drainage devices (GDD) are no longer a last resort and can be considered a suitable option for the management of uncontrolled pediatric glaucoma after angle surgery failure.
Abstract: Bioengineered materials are used as a substitute in many fields of medicine, especially in plastic surgery and in burns. In ophthalmic plastic surgery they can be used for covering large tissue defects or as a tarsal plate substitute, in cases when it is not possible to use conventional surgical techniques. We have searched PubMed and Web of Science scientific databases. We can generally categorize skin substitutes by the type of tissue used—we distinguish autografts, allografts, and xenografts. There are also completely synthetic substitutes. The aim of our article was to summarize the current state of knowledge and to sum up all the clinical applications of bioengineered materials in the periocular region. There are only a few scientific articles about this topic and lack of prospective randomized studies aimed on use of bioengineered materials in periocular region. Nevertheless, there are many articles describing successful case reports or case reports series. According to literature, bioengineered materials are the most commonly used in big traumas or large surgical defects, especially in oculoplastic tumour surgery. Bioengineered dermal substitutes are not frequently used in the periocular region. Dermal substitutes are useful, when it is not possible to close the defect with any other conventional surgical technique.
Background: Using a randomized controlled trial (RCT), to assess the efficacy of the folded technique of self-adherent wrap to eyes after orbital tumour extirpation and compare it with the classic technique.
Methods: A single-centre, prospective, randomized, controlled study was conducted among 128 patients who underwent orbital tumour extirpation in this study. The folded and classic techniques of applying self-adherent wraps were randomly allocated to patients (1:1). The primary endpoint was the interface pressure on the affected eye. Secondary efficacy endpoints were the interface pressure above and below the ear of the affected side, above the ear of the non-affected side, and discomfort scores. Postoperative complications were observed for 24 hours.
Results: The interface pressure with the folded technique on the affected eye was neither inferior nor superior to the classic technique (1.33±0.07 vs. 1.41±0.09 mmHg, P=0.480). Most importantly, the pressure at three other points outside of the affected eye, including above and below the ear of the affected side, and above the ear of the non-affected side, were significantly higher when using the classic technique than when using the folded technique (P=0.041, 0.019, and 0.047, respectively). Discomfort scores were higher in the classic technique group than in the folded technique group (2.93±0.30 vs.1.52±0.19, P≤0.001).
Conclusions: Findings demonstrated the advantages of using folded technique to apply self-adherent wrap for wounds after orbital tumour extirpation with lower interface pressure outside of the affected eye and patient discomfort scores, without influencing pressure on the affected eye comparing with the classic technique.