Review Article

Amniotic membrane transplantation: an updated clinical review for the ophthalmologist

:22-56
 
Although amniotic membrane transplantation (AMT) has long been used as an essential surgical technique for ocular surface reconstruction, its role continues to evolve and expand. In the management of numerous ocular surface disorders, ranging from inflammatory to infectious, traumatic to neoplastic, the ability to perform AMT is a valuable addition to the skillset of any ophthalmologist. The purpose of this paper is to provide ophthalmologists with an updated, evidence-based review of the clinical indications for AMT in corneal and conjunctival reconstruction, reviewing its common and even experimental applications known to date. The methods of amniotic membrane preservation, the available commercial amniotic membrane products to date, and future directions for amniotic membrane use, including amniotic membrane extract eye drops (AMEED), are also discussed. It is paramount for ophthalmologists to stay up-to-date on the applications of AMT so as to effectively incorporate this versatile treatment modality into their practice,both in the operating room and in the clinic. By familiarizing the general ophthalmologist with its diverse applications, we hope to motivate general ophthalmologists to incorporate the use of AMT into their clinical practice, or provide guidance on how to recognize when referral to a corneal specialist for amniotic membrane application is prudent.
Original Article

Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices

:22-77
 
Background: To compare two swept-source optical coherence tomography (SS-OCT) biometers,IOLMaster 700 and ANTERION.
Methods: This is a retrospective study. Biometric measurements of cataract patients performed between March and July 2021 in the Department of Ophthalmology, United Christian Hospital, Hong Kong, were reviewed. Patients scheduled for cataract surgery were measured with both SS-OCT devices on the same day.The following biometry parameters were compared: keratometry (K), total keratometry (TK), axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and the predicted intraocular lens (IOL) power to achieve emmetropia. To assess the agreement between the devices, Bland-Altman analysis with 95% limits of agreement (LoA) were used.
Results: In total, 92 eyes of 47 subjects were measured with both devices. There were statistically significant differences between the two biometers for most measurements (P<0.05) except for flat K, AL and IOL power when using the right eyes for analysis. For the left eyes, there were statistically significant differences in the measurements from the two biometers in all parameters except for flat and steep K. The ANTERION did not obtain ACD, AL and LT in 2 (2.17%), 1 (1.09%) and 5 cases (5.43%) respectively.
Conclusions: The two biometers showed a clinically acceptable agreement in most parameters. Comparisons showed significant differences in most parameters but not clinically relevant except for the TK and WTW, and these two parameters should not be used interchangeably between the devices.
Review Article

A narrative review of ocular surface disease considerations in the management of glaucoma

:22-59
 
Background and Objective: Ocular surface disease (OSD) is a common yet often overlooked consideration in the management of patients with glaucoma. Although there have been several review articles summarizing the relationship between glaucoma medications and OSD, there is a relative absence of such articles on the effects of glaucoma surgical treatments. Here, we present a comprehensive review of the literature regarding the relationship of glaucoma management and OSD, with an emphasis on surgical considerations.
Methods: PubMed, Google Scholar, and Cochrane Review searches were performed using the following search terms: ocular surface, dry eye, minimally invasive glaucoma surgeries (MIGS), trabeculectomy,glaucoma medications. The titles and abstracts from those searches were screened for relevance to our review topics. Publications were included if the subjects included glaucoma patients, and if ocular surface outcomes were described. Non-English papers were excluded.
Key Content and Findings: Topical glaucoma medications frequently cause adverse effects on the ocular surface, both through direct action of the medications themselves as well as through toxicity from their associated preservatives. Optimization of the ocular surface may improve medication compliance rates.Traditional surgical treatments for glaucoma, such as trabeculectomy, can exacerbate OSD by disrupting the ocular surface but can also reduce the need for chronic medications. Optimization of ocular surface health is imperative in reducing trabeculectomy complication rates, while also potentially reducing the need for trabeculectomy in patients that are able to achieve intraocular pressure control through improved drop tolerability. The introduction of MIGS represents a promising alternative to existing therapies and has been shown to alleviate the overall medication burden. It would be reasonable to assume that decreasing the medication burden could reduce OSD prevalence and severity. However, more research is needed to directly assess the extent of improvement seen after MIGS.
Conclusions: A comprehensive understanding of the importance of OSD in medical and surgical management of glaucoma is essential in optimizing patient care and improving outcomes.
Review Article

A narrative review of limbal stem cell deficiency & severe ocular surface disease

:22-35
 
Background and Objective: Limbal stem cell deficiency (LSCD) describes the clinical condition when there is dysfunction of the corneal epithelial stem/progenitor cells and the inability to sustain the normal homeostasis of the corneal epithelium. The limbal stem cells are located in a specialized area of the eye called the palisades of Vogt (POV). There have been significant advances in the diagnosis and management of LSCD over the past decade and this review focuses on the pathophysiology of LSCD, its clinical manifestations, diagnosis, and causes.
Methods: Papers regarding LSCD were searched using PubMed to identify the current state of diagnosis and causes of LSCD published through to June 2022. 
Key Content and Findings: LSCD is clinically demonstrated by a whorl-epitheliopathy, loss of the POV, and conjunctivalization of the cornea. The diagnosis of this condition is based on clinical examination and aided by the use of impression cytology, in vivo confocal microscopy, and anterior segment optical coherence tomography (asOCT). There are many causes of LSCD, but those which are most common include chemical injuries, aniridia, contact lens wear, and Stevens-Johnson syndrome (SJS).
Conclusions: While this condition is most commonly encountered by corneal specialists, it is important that other ophthalmologists recognize the possibility of LSCD as it may arise in other co-morbid eye conditions.
Editorial
Original Article

Changes in crystalline lens parameters during accommodation evaluated using swept source anterior segment optical coherence tomography

:-
 

Backgrounds: To assess changes in anterior segment biometry during accommodation using a swept source anterior segment optical coherence tomography (SS-OCT).

Methods: One hundred-forty participants were consecutively recruited in the current study. Each participant underwent SS-OCT scanning at 0 and ?3 diopter (D) accommodative stress after refractive compensation, and ocular parameters including anterior chamber depth (ACD), anterior and posterior lens curvature, lens thickness (LT) and lens diameter were recorded. Anterior segment length (ASL) was defined as ACD plus LT. Lens central point (LCP) was defined as ACD plus half of the LT. The accommodative response was calculated as changes in total optical power during accommodation.

Results: Compared to non-accommodative status, ACD (2.952±0.402 vs. 2.904±0.382 mm, P<0.001), anterior (10.771±1.801 vs. 10.086±1.571 mm, P<0.001) and posterior lens curvature (5.894±0.435 vs. 5.767±0.420 mm, P<0.001), lens diameter (9.829±0.338 vs. 9.695±0.358 mm, P<0.001) and LCP (4.925±0.274 vs. 4.900±0.259 mm, P=0.010) tended to decreased and LT thickened (9.829±0.338 vs. 9.695±0.358 mm, P<0.001), while ASL (6.903±0.279 vs. 6.898±0.268 mm, P=0.568) did not change significantly during accommodation. Younger age (β=0.029, 95% CI: 0.020 to 0.038, P<0.001) and larger anterior lens curvature (β=?0.071, 95% CI: ?0.138 to ?0.003, P=0.040) were associated with accommodation induced greater steeping amplitude of anterior lens curvature. The optical eye power at 0 and ?3 D accommodative stress was 62.486±2.284 and 63.274±2.290 D, respectively (P<0.001). Age was an independent factor of accommodative response (β=?0.027, 95% CI: ?0.038 to ?0.016, P<0.001).

Conclusions: During ?3 D accommodative stress, the anterior and posterior lens curvature steepened, followed by thickened LT, fronted LCP and shallowed ACD. The accommodative response of ?3 D stimulus is age-dependent.

Review Article

Conjunctival flaps for the treatment of advanced ocular surface disease—looking back and beyond

:-
 
Conjunctival flaps have previously proven to be effective in preserving the globe for individuals with severe ocular surface disease. Infectious keratitis, neurotrophic keratitis, nontraumatic corneal melts, descemetoceles, perforations, and corneal burns are all indications for this procedure. The flaps promote nutrition, metabolism, structure, and vascularity, as well as reduce pain, irritation, inflammation, and infection. Furthermore, patients avoid the emotional and psychological repercussions of enucleation or evisceration, while requiring fewer postoperative medications and office visits. Currently, fewer flaps are performed due to the emergence of additional therapeutic techniques, such as serum tears, bandage lenses, corneal grafting, Oxervate, amniotic membrane, and umbilical cord grafting. However, despite newer conservative medical methods, conjunctival flaps have been demonstrated to be useful and advantageous. Moreover, future technologies and approaches for globe preservation and sight restoration after prior conjunctival flaps are anticipated. Herein, we review the history, advantages, and disadvantages of various surgical techniques: Gundersen’s bipedicle flap, partial limbal advancement flap, selective pedunculated conjunctival flap with or without Tenon’s capsule, and Mekonnen’s modified inferior palpebral-bulbar conjunctival flap. The surgical pearls and recommendations offered by the innovators are also reviewed, including restrictions and potential complications. Procedures for visual rehabilitation in selective cases after conjunctival flap are reviewed as well.
Case report

Case report: simultaneous femtosecond laser astigmatic keratotomy and toric intraocular lens implantation in femtosecond laser-assisted cataract surgery in a patient with surgically induced high corneal astigmatism

:-
 

Background: Femtosecond laser astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation have been studied individually for comparison to treat astigmatism at cataract surgery. We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty (LTK) in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery (FLACS). This is the first report of both procedures combined simultaneously, with or without history of LTK.

Case Description: A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004, with subsequent surgically induced high corneal astigmatism, and with age-related nuclear cataract of both eyes. IOL master demonstrated +7.71 diopters of astigmatism at 163 degree right eye and +3.29 diopters of astigmatism at 4 degree left eye. After extensive discussion of the risks and benefits, the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions (RIs) and toric IOL (Alcon SN6AT9) right eye; FLACS with toric IOL (Alcon SN6AT7) alone left eye. At 2-year follow-up, uncorrected visual acuity was 20/30 right eye, 20/25 left eye. His best corrected visual acuity was 20/25 (+0.25 +1.00 axis 21) right eye and 20/20 (plano +0.25 axis 90) left eye; his best corrected near visual acuity was J1+ with add +2.50 diopters right eye and left eye.

Conclusions: Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery. An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9, in our case, simultaneously, which can achieve an excellent long term visual outcome.

Technical Note

Allogeneic sclera graft combined autologous conjunctival flap for repairing the emergent corneal perforation

:-
 

Abstract: To report a palliative and alternative surgical procedure, allogeneic sclera graft combined with autologous conjunctival flap (ASGACF), employing to repair the large emergent corneal perforation. The detail protocol of the surgical procedure was characterized and four representative cases were reviewed. An allogeneic sclera graft and recipient bed were prepared as the traditional penetrating keratoplasty (PK). And then sutured the sclera graft to the bed with 10-0 nylon suture and covered with a pedicled autologous conjunctival flap in half size. In the follow-up, the ASGACF repaired all of the corneal perforations and restored the integral walls of eyeballs, in spite of one who underwent a second surgery. This surgical procedure provided a palliative method to repair the large emergent corneal perforation while there is the lack of a corneal graft.

Original Article

Supracapsular implantation with optic capture of posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract

:-
 

Background: To assess the safety and efficacy of supracapsular implantation with optic capture of the posterior chamber intraocular lens in Chinese children with aphakic after traumatic cataract.

Methods: It was a retrospective case series study. Fifteen cases (15 eyes) Chinese children received supracapsular implantation with optic capture of the posterior chamber intraocular lens. Pre- and post-operative visual acuities were recorded. Intra- and post-operative complications were observed. The follow-up period ranged from 7 to 43 (28.7±7.2) months.

Results: Implantation of optic capture of the posterior chamber intraocular lens was successfully performed in 15 eyes. The best corrected visual acuity (BCVA) ranged from 0.3 to 1.0 (0.61±0.19). No optic axis opaque was found in 15 eyes with optic capture. The major complications of optic capture were iris posterior synechia and intraocular lens (IOL) precipitates. Intraocular dislocation was found in one case three weeks after the operation.

Conclusions: Supracapsular implantation with optic capture of the posterior chamber intraocular lens is safe and effective for the treatment of traumatic cataract in Chinese children.