Review Article

Use of a handheld slit beam intraoperatively to assist in big bubble formation during deep anterior lamellar keratoplasty

2018,3(10):-
Alexander S. Davis,2,Peter Bedard,3,Joshua H. Hou

Abstract: Deep anterior lamellar keratoplasty (DALK) is preferred over conventional penetrating keratoplasty (PKP) for the treatment of anterior corneal opacities or ectasias due to decreased risk of endothelial rejection. However, DALK remains surgically challenging, largely due to challenges associated with achieving consistent pneumo-dissection of posterior stroma from the underlying pre-Descemet’s or Descemet’s membrane (DM). Air must be injected at sufficient depth in the corneal stroma in order to achieve successful pneumo-dissection, but advancing a needle too deep into the cornea can lead to perforation of DM. We describe here a novel technique using a handheld slit lamp (Eidolon model 510L, Eidolon Optical LLC, Natick, MA, USA) to assist in creation of the big-bubble in DALK surgery. Use of a handheld slit beam intraoperatively is a safe, relatively inexpensive, and effective technique for increasing the success of big-bubble formation in DALK procedures.

Current Issue
  • 眼科学报

    Executive director:Ministry of Education of the People's Republic of China
    Host: Sun Yat-sen University
    Undertake: Zhongshan Ophthalmic Center, Sun Yat-sen University
    Editors-in-Chief: 林浩添
    Executive director:Ministry of Education of the People's Republic of China
    Host: Sun Yat-sen University
    Browse
  • Eye Science

    Executive director:Ministry of Education of the People's Republic of China
    Host: Sun Yat-sen University
    Undertake: Zhongshan Ophthalmic Center, Sun Yat-sen University
    Editors-in-Chief: 林浩添
    Executive director:Ministry of Education of the People's Republic of China
    Host: Sun Yat-sen University
    Browse
Publishing Information
Copyright of Zhongshan Ophthalmic Center, Sun Yat-sen University粤ICP备:11021180